Maximum Demand Calculator
Enter the connected load for each type of circuit in a dwelling and the tool applies the usual On-Site Guide diversity allowances to give an assessed maximum demand.
Last reviewed
How diversity is applied
Adding up every connected load gives a figure far higher than an installation ever draws, because the loads do not all peak together. The On-Site Guide gives allowances for each type of circuit in a single dwelling, and this tool applies them like this:
Showers: largest + 25% of the rest · Water heating, heating, EV, other: 100%
Each load is converted to a current at 230 V, the allowance is applied, and the results are added to give the assessed maximum demand. That current then sets the supply, the main switch and the tails.
Where the figures come from
These are the single-household allowances from the IET On-Site Guide. Other premises, blocks of flats and three-phase supplies use different tables, and modern loads such as EV charging and heat pumps are often taken at full load unless a load-management scheme is in place.